Fire Safety Tips for Your Connecticut Home With an Attached Garage  
Monday, December 26, 2011 at 3:11PM
Judy in Guest Contributor-Building Inspections

An attached garage is a garage that is physically attached to a house. Fires that begin in attached garages are more likely to spread to living areas than fires that originate in detached garages. For this reason, combined with the multitude of flammable materials commonly found in garages, attached garages should be adequately sealed from living areas. A properly sealed attached garage will ideally restrict the potential spread of fire long enough to allow the occupants time to escape the home or building.


Why are garages (both attached and detached) fire hazards?

Doors

The 2006 edition of the International Residential Code (IRC) states the following concerning doors that separate garages from living areas:

R309.1 Opening Penetration
Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and the residence shall be equipped with solid wood doors not less than 1-3/8” (35 mm) in thickness, solid- or honeycomb-core steel doors not less than 1-3/8” (35 mm) thick, or 20-minute fire-rated doors.

In addition, InterNACHI inspectors can check for the following while inspecting doors that separate garages from living areas:

Walls and Ceilings

The 2006 edition of the IRC states the following concerning garage walls and ceilings:

          R309.2 Separation Required 
The garage shall be separated from the residence and its attic area by not less than ½-inch (12.7 mm) gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5/8-inch (15.9 mm) Type X gypsum board or equivalent. Where the separation is a floor-ceiling assembly, the structure supporting the separation shall also be protected by not less than ½-inch (12.7 mm) gypsum board or equivalent. Garages located less than 3 feet (914 mm) from a dwelling unit on the same lot shall be protected with not less than 1/2–inch (12.7 mm) gypsum board applied to the interior side of exterior walls that are within this area. Openings in these walls shall be regulated by Section 309.1. This provision does not apply to garage walls that are perpendicular to the adjacent dwelling unit wall.

In addition, inspectors can check for the following while inspecting walls and ceilings:

Ducts

The 2006 edition of the IRC states the following concerning ducts that penetrate garage walls and ceilings:

R309.1.1 Duct Penetration

Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gauge (0.48 mm) steel sheet or other approved material, and shall have no openings in the garage.

Dryer exhaust ducts that penetrate garage walls are serious fire hazards. These ducts are generally made from plastic and will easily melt during a fire, creating a large breach in the firewall.

Floors

The 2006 edition of the IRC states the following concerning floors in garages:

          R309.3 Floor Surface 
Garage floor surfaces shall be of approved, non-combustible material. The area of the floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway.

Inspectors should also check for the following:

Concerning items placed on the floor, inspectors should check for the following:

General safety tips that inspectors can pass onto their clients:

In summary, attached garages should be sealed off from the living space so that fire may be contained.
by Nick Gromicko, Rob London and Kenton Shepard
Nick Gromicko, FOUNDER. http://www.nachi.org
International Association of Certified Home Inspectors (InterNACHI) is the world's most elite, non-profit inspection association.
President, ComInspect, www.cominspect.com
Director, Master Inspector Certification Board, www.certifiedmasterinspector.org
Author, 15 books and Co-Host of  http://www.NACHI.TV
Article originally appeared on Fairfield County CT Real Estate & Homes for Sale in Easton, Fairfield, Norwalk, Trumbull & Westport, Connecticut (http://www.thectrealtyblog.com/).
See website for complete article licensing information.